WINDOW
REQUIREMENTS
Permits, Egress Windows, Smoke Alarms, and Safety Glazing
Windows
Permits
The installation or replacement of a window or
windows requires a permit and inspection. This includes
retrofit windows in existing frames.
Daly City issues window permits to the person
doing the work. A homeowner who is capable of doing
the work can obtain them, or they are issued to a California
licensed contractor with a current Daly City business
license.
Egress Windows
Windows may be replaced in kind in bedrooms provided:
1) The existing window/s met egress requirements of
the code in effect at time the building was built.
2) The window opening/s have not been made smaller.
3)
The
window shall be made compliant with current code if
it can be made so by changing its type or configuration.
Structural or framing changes are not required, but
may be made voluntarily. Lowering the sill height to
the code maximum of 44 inches is
recommended but not required.
Example
1: An XOX bedroom window has only a 16-inch openable
width. It shall not be replaced in kind. An XO window
with a code complying 20-inch width is needed.
Example
2: A two-foot wide by four-foot tall single-hung window
is removed. It shall not be replaced in kind. A casement
window is needed that will provide the code required
minimum 20-inch openable width, 24-inch height and
5.7 square foot area.
To meet current egress requirements, all of
the following must be met:
1) A finished sill height above the finished floor of
44" or less.
2) A minimum opening of 5.7 square feet net clear
area.
3) A minimum net clear opening dimension of 20"
in width.
4) A minimum net clear opening dimension of 24"
in height.
__Note: The minimum
dimension in both directions will not meet the egress
area requirement.
Changes in the size of the window opening will
require the window/s meet current egress requirements.
Window openings that are altered will require appropriate
inspections such as frame, insulation, shear wall, sheetrock,
stucco wrap and wire, scratch coat and final.
Security bars shall not be installed over egress
windows unless the security bars open without the use
of a key and without any special knowledge or effort.
Smoke Alarms
Work that exceeds $1,000 in valuation requires
the installation of smoke alarms in every bedroom, on
each level and centrally located in adjoining hallways.
The permit applicant/contractor/installer is
responsible for the providing and installing the required
smoke alarms.
Battery operated smoke alarms are adequate in
existing rooms but cannot be used to replace hardwired
smoke alarms.
Smoke alarms require inspection to verify installation,
location and operation.
Safety
Glazing-Windows
Glazing less than 60" above the drain inlet
in hot tubs, whirlpools, saunas, steam rooms, bathtubs
and showers shall be tempered.
Glazing in fixed or openable panels adjacent
to a door, where the nearest exposed edge of the glazing
in within a 24" arc of either vertical edge of
the door in a closed position and where the bottom
exposed edge is less than 60" above the walking
surface, shall be tempered.
Glazing in walls enclosing stairway landings
or within 5 feet of the bottom and top stairways where
the bottom edge of the glass is less than 60" above
a walking surface shall tempered.
Glazing in individual fixed or operable windows
shall be safety type if the window in question meets
all of the following conditions:
__1) The exposed area of
the individual pane is greater than 9 square feet.
__2) The exposed bottom
edge is less than 18" above the floor.
__3) The exposed top edge
is greater than 36" above the floor.
__4) There are one or more
walking surfaces within 36" horizontally of the
plane of the glazing
If
you would like additional information, please telephone
the Building Division at (650) 991-8061.